Acoustic signals & error messages - Siros L
-
Stelos 800 L
Stelos: Safety Instructions – read before use | Environment Stelos: Firmware update Stelos: User Interface | Controls | Functions | Handling Stelos: Technical Data Stelos: Remote control | Flash triggering Stelos: Power supply | Battery Stelos: Maintenance | Repair | Warranty Stelos: Accessories & Spare Parts Stelos: Error messages
-
Satos
Satos: Safety Instructions – read before use | Environment Satos: Firmware update Satos Satos: User Interface | Controls | Functions | Handling Satos: Technical Data Satos: Remote control | Flash triggering Satos: Power supply | Battery Satos: Maintenance | Repair | Consumables | Spare parts | Guarantee Satos: Accessories Satos: Charging station for up to 4 slide-in batteries
- Pulso L
-
Siros S
Siros S: Safety Instructions – read before use | Environment Siros S: Firmware update Siros S: User Interface | Controls | Functions | Handling Siros S: Technical Data Siros S: Remote control | Flash triggering Siros S: Power supply Siros S: Maintenance | Repair | Consumables | Spare parts | Guarantee Siros S: Accessories
-
Siros L
Siros L: Safety Instructions – read before use | Environment Siros L: Firmware update Siros L Siros L: User Interface | Controls | Functions | Handling Siros L: Technical Data Siros L: Remote control | Flash triggering Siros L: Power supply | Battery Siros L: Maintenance | Repair | Consumables | Spare parts | Guarantee Siros L: Accessories
- Scoro E + S
- Move 1200 L
- RFS 2.1
- RFS 2.2
-
RFS 3
RFS 3: Safety Instructions – read before use | Environment RFS 3: Scope of delivery and operating elements RFS 3: User Interface | Controls | Functions | Handling RFS 3: Firmware Update RFS 3.0 RFS 3: Compatibility RFS 3: Technical Data RFS 3: Maintenance | Repair | Consumables | Spare parts | Guarantee RFS 3: Trouble shooting
- Pulso G, Unilite and Picolite
- LED F160
- Scope D50
- Compatibility (Lamp <-> light shaper | Lamp <-> power pack)
- Locate your distributor or dealer
-
Stelos 800 L
-
Satos
-
Pulso L
-
Siros S
-
Siros L
-
Scoro E + S
-
Move 1200 L
-
RFS 2.1
-
RFS 2.2
-
RFS 3
-
Pulso G, Unilite and Picolite
-
LED F160
-
Scope D50
-
Compatibility (Lamp <-> light shaper | Lamp <-> power pack)
-
Locate your distributor or dealer
Acoustic signals
| Beep sound | end of charging or discharging |
| Double beep | energy demand above or below energy control setting via RFS 2.1 / RFS 2.2 transmitter |
Message in display (*)
|
Fault 1 (F1) |
No flash on release Is the ignition wire correctly connected? Is the flash tube correctly installed? Otherwise replace flashtube. If this fault still appears, unit must be sent to Service for repair. |
|
Fault 2 (F2) |
Afterglow Switch the unit off (wait 60 sec.) and then switch it on again. If this fault occurs repeatedly, the flash tube is defective. Please replace it with a new flash tube. If this fault still appears, unit must be sent to Service for repair. |
|
Fault 3 (F3) |
No charging Unit must be sent to Service for repair. |
|
Fault 4 (F4) |
Overcharging Unit must be sent to Service for repair. |
| th |
Thermal alarm, capacitors overheated A cooling phase of approximately 20 minutes starts. Do not switch off the unit! |
* Error messages are always also indicated by the red cognition light.