Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • formulaire de contact
French
US English (US)
FR French
DE German
  • Home
  • Scope D50

Minimum system requirements

Written by Anja Fricker

Updated at March 8th, 2024

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Satos
    Consignes de sécurité – à lire avant utilisation | Environnement Firmware Update Satos Interface utilisateur | Affichages | Fonctions | Manutention Données techniques Télécommande et déclenchement du flash Alimentation électrique | batterie Entretien | Réparation | Consommables | Pièces de rechange | Garantie Accessoires Station de charge pour 4 batteries enfichables
  • Pulso L
    Consignes de sécurité – à lire avant utilisation | Environnement Firmware Update Pulso L Interface utilisateur | Affichages | Fonctions | Manutention Données techniques Entretien | Réparation | Consommables | Pièces de rechange | Garantie Accessoires
  • Siros S
    Consignes de sécurité – à lire avant utilisation | Environnement Firmware update Siros S Interface utilisateur | Affichages | Fonctions | Manutention Données techniques Télécommande et déclenchement du flash Alimentation électrique Entretien | Réparation | Consommables | Pièces de rechange | Garantie Accessoires
  • Siros L
    Consignes de sécurité – à lire avant utilisation | Environnement Firmware Update Siros L Interface utilisateur | Affichages | Fonctions | Manutention Données techniques Télécommande et déclenchement du flash Alimentation électrique | batterie Entretien | Réparation | Consommables | Pièces de rechange Accessoires
  • Scoro E + S
    Consignes de sécurité - à lire avant utilisation | Environnement Interface utilisateur | Affichages | Fonctions | Manutention Données techniques Télécommande et déclenchement du flash Entretien | Réparation | Consommables | Pièces de rechange | Garantie
  • Move 1200 L
    Consignes de sécurité – à lire avant utilisation | Environnement Firmware update Move Données techniques Interface utilisateur | Affichages | Fonctions | Manutention Télécommande et déclenchement du flash Alimentation électrique | batterie Entretien | Réparation | Consommables | Pièces de rechange
  • RSF 2.2
    Consignes de sécurité – à lire avant utilisation Étendue de la livraison et aperçu du produit Transmetteur RFS 2.2 en tant qu'émetteur Transmetteur RFS 2.2 en tant qu'récepteur Données techniques Mise à jour du firmware RFS 2.2
  • RFS 2.1
    Consignes de sécurité – à lire avant utilisation Étendue de la livraison et aperçu du produit Fonctionnement en émetteur ou en récepteur Fiche de données RFS 2.1 Transceiver RFS 2.1 comme émetteur Résolution des problèmes Accessoires
  • RFS 3
    Consignes de sécurité – à lire avant utilisation | Environnement Contenu de la livraison et éléments de commande Interface utilisateur | Affichages | Fonctions | Manutention Mise à jour du firmware RFS 3 Compatibilité Données techniques Entretien | Réparation | Consommables | Pièces de rechange | Garantie Résolution des problèmes
  • Pulso G, Unilite et Picolite
  • LED F160
    Consignes de sécurité – à lire avant utilisation Mises à jour du firmware LED F160 Interface utilisateur | Affichages | Fonctions | Manutention Données techniques Entretien | Réparation | Consommables | Pièces de rechange | Garantie Accessoires
  • Scope D50
  • Compatibilité ( Torche <-> Modeleur de lumière | Torche <-> Générateur)
  • Localisez votre distributeur ou revendeur
+ More
  • Satos

    • Pulso L

      • Siros S

        • Siros L

          • Scoro E + S

            • Move 1200 L

              • RSF 2.2

                • RFS 2.1

                  • RFS 3

                    • Pulso G, Unilite et Picolite

                      • LED F160

                        • Scope D50

                          • Compatibilité ( Torche <-> Modeleur de lumière | Torche <-> Générateur)

                            • Localisez votre distributeur ou revendeur

                              Table of Contents

                              Recommendation

                              Lenses 
                              Fixed focal length macro lenses (also tilt-shift lenses) with a focal length between 50 mm (1.97”) and 105 mm (4.13”). Basically, also other lenses are possible as long as the maximum angle of view is not exceeded. 


                              Max. depth of insertion of the lens
                              Maximum depth of insertion: 7 cm (2.76”). The max. depth of insertion, measured from the outer edge of the Scope D50, should not be exceeded in order to avoid a shadow of the lens on the object. 


                              Max. angle of view 
                              80° with a depth of insertion of 0 cm (0”)
                              115° with a depth of insertion of 7 cm (2.76”)
                              The max. angle of view should not be exceeded in order to avoid lens flares. 


                              Object size and distances 
                              Max. diameter of the object: 32 cm (12.60”) 
                              Max. length of the edge of a square object:
                              22 cm (8.66”)
                              Max. distance lower edge Scope D50 to surface of the object: 15 cm (5.90”) 
                              Variable height due to combination of supporting and adjustable feet: 1.5 - 6 cm (0.59” - 2.36”) and 
                              10.5 - 15 cm (4.13” - 5.90”) 


                              Hardware and operating system 
                              PC: Windows 10 
                              Mac: Mac OS 10.11 
                              RAM: 4 GB 
                              Processor speed: 2 GHz 
                              Free disk space: 500 MB 
                              (for the setup of the programme)
                               

                              Form of the object 
                              In general, objects with a slighter bend of the surface are more suitable than those with a strong bend. The latter could produce a shadow on the object itself.


                               

                              Recommendation


                              Ideally, the surface of the object should be placed flush with the lower edge of Scope D50.

                               

                               

                              système minimal exigences minimales

                              Was this article helpful?

                              Yes
                              No
                              Give feedback about this article

                              Related Articles

                              • Installation en 9 étapes
                              • Étendue de la livraison
                              • Interaction of Scope D50 & camera
                              • Données techniques Scope D50
                              • Informations sur la protection de l'environnement

                              Copyright 2025 – broncolor.

                              Knowledge Base Software powered by Helpjuice

                              Expand