Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Us
English (US)
US English (US)
FR French
DE German
  • Home
  • Scoro E + S
  • Remote control | Flash triggering

Remote Control

Written by Anja Fricker

Updated at September 17th, 2024

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Satos
    Safety Instructions – read before use | Environment Firmware update Satos User Interface | Controls | Functions | Handling Technical Data Remote control | Flash triggering Power supply | Battery Maintenance | Repair | Consumables | Spare parts | Guarantee Accessories Charging station for up to 4 slide-in batteries
  • Pulso L
    Safety Instructions – read before use | Environment Firmware update Pulso L User Interface | Controls | Functions | Handling Technical Data Maintenance | Repair | Consumables | Spare parts | Guarantee Accessories
  • Siros S
    Safety Instructions – read before use | Environment Firmware update Siros S User Interface | Controls | Functions | Handling Technical Data Remote control | Flash triggering Power supply Maintenance | Repair | Consumables | Spare parts | Guarantee Accessories
  • Siros L
    Safety Instructions – read before use | Environment Firmware update Siros L User Interface | Controls | Functions | Handling Technical Data Remote control | Flash triggering Power supply | Battery Maintenance | Repair | Consumables | Spare parts | Guarantee Accessories
  • Scoro E + S
    Safety instructions - read before use | Environment User interface | Controls | Functions | Handling Technical Data Remote control | Flash triggering Maintenance | Repair | Consumables | Spare parts | Guarantee
  • Move 1200 L
    Safety Instructions – please read before use | Environment Firmware update Move User Interface | Functions | Handling | Controls Technical Data Remote control | Flash triggering Power supply | Battery Maintenance | Repair | Consumables | Spare parts
  • RFS 2.1
    Safety Instructions - read before use Scope of Delivery and product overview Technical Data Operation as transmitter or receiver RFS 2.1 transceiver as transmitter Trouble shooting Accessories
  • RFS 2.2
    Safety Instructions - read before use Scope of Delivery and product overview RFS 2.2 transceiver as transmitter RFS 2.2 transceiver as receiver Technical Data Firmware Update RFS 2.2
  • RFS 3
    Safety Instructions – read before use | Environment Scope of delivery and operating elements User Interface | Controls | Functions | Handling Firmware Update RFS 3.0 Compatibility Technical Data Maintenance | Repair | Consumables | Spare parts | Guarantee Trouble shooting
  • Pulso G, Unilite and Picolite
  • LED F160
    Safety instructions - read before use | Environment Firmware Update LED F160 User Interface | Controls | Functions | Handling Technical Data Maintenance | Repair | Error Messages| Guarantee Accessories
  • Scope D50
    Videos
  • Compatibility (Lamp <-> light shaper | Lamp <-> power pack)
  • Locate your distributor or dealer
+ More
  • Satos

    • Pulso L

      • Siros S

        • Siros L

          • Scoro E + S

            • Move 1200 L

              • RFS 2.1

                • RFS 2.2

                  • RFS 3

                    • Pulso G, Unilite and Picolite

                      • LED F160

                        • Scope D50

                          • Compatibility (Lamp <-> light shaper | Lamp <-> power pack)

                            • Locate your distributor or dealer

                              The remote control system has 20 channels (studio addresses) with up to 20 unit addresses per channel. The channels assign each an independent workstation. Each flash unit within a workstation is identifiable by its own unit address. Every other workstation can each operate up to 20 flash units. Therefore, flash units of multiple workstations are clearly identifiable. A PC or Macintosh computer, or an RFS transmitter can control all the flash units of a studio workstation (channel / studio address).

                               

                              Computer connection with RFS (Radio Frequency System)
                              All Scoro A power packs have a built in interface which allows remote control or flash triggering of the power pack via radio from RFS transmitter, as well as RFS transceiver from PC or Macintosh computer. Therefore all the Scoro power pack functions can be comfortably controlled from a digital workstation (see diagram). 

                              PC / Macintosh screen display

                              Remote control channels (RFS studio address)
                              Remote control by means of RFS may be performed via separate channels (studio workstations). These can be set in the LCD menu under "studio address" (see section 14.14). All flash units within a studio workstation must have the same channel number (studio address).

                              RFS unit addresses
                              Unit addresses will be assigned to each power pack for individual control. (See LCD menu "unit address", section 14.15).

                              Computer connection with cable
                              Scoro units are equipped with a computer connection socket (3). This allows operation of the power pack from the computer via cable. Each channel can control up to 20 units. Hence, Scoro power packs can be remotely controlled by cable with the Bron studio software.

                              wireless control distant operation

                              Was this article helpful?

                              Yes
                              No
                              Give feedback about this article

                              Related Articles

                              • Minimum system requirements
                              • Safety Instructions
                              • Setting the lamp channel - RFS 2.2 transceiver as transmitter

                              Copyright 2025 – broncolor.

                              Knowledge Base Software powered by Helpjuice

                              Expand