Safety Instructions – read before use | Environment Firmware update Satos User Interface | Controls | Functions | Handling Technical Data Remote control | Flash triggering Power supply | Battery Maintenance | Repair | Consumables | Spare parts | Guarantee Accessories Charging station for up to 4 slide-in batteries
- Pulso L
- Siros S
- Siros L
- Scoro E + S
- Move 1200 L
- RFS 2.1
- RFS 2.2
- Pulso G, Unilite and Picolite
- LED F160
- Scope D50
- Compatibility (Lamp <-> light shaper | Lamp <-> power pack)
- Locate your distributor or dealer
Table of Contents
Mains voltage
As a standard feature, all the Scoro power packs are supplied as multi-voltage units.
They automatically adapt to the respective mains voltage.
Scoro power packs A2S and A4S deliver for all operating voltages (85-240 V)
constant 1600 J or 3200 J.
Scoro power packs A2 and A4 (230V) can also be operated on 100 V or 120 V.
However, the following limitations apply for 100 V –120 V:
> 800 J are available instead of 1600 J (Scoro A2).
> 1600 J are available instead of 3200 J (Scoro A4).
Furthermore, stroboscopic and speed mode are not possible.
It is not possible to influence the flash duration and colour temperature.
Attention
Ensure that the operating voltage of the modelling lamp corresponds to the local
mains supply (max. 650 W on 200-240 V or 300 W on 100-120V).
Earthed mains (AC -line)
Whenever possible, connect unit to current supply always using an earthed mains plug.
Start up
Use the mains (AC-line) switch (1) to power up the unit. During the charging process, the digital
master power display (12) flashes, after which, it becomes continuous (see section 12, "Lamp
compatibility").