Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Us
English (US)
US English (US)
FR French
DE German
  • Home
  • Siros L
  • User Interface | Functions | Handling | Controls

Overview of main menu functions - Move 1200 L

Written by Myrtha Chollet

Updated at February 21st, 2023

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Stelos 800 L
    Stelos: Safety Instructions – read before use | Environment Stelos: Firmware update Stelos: User Interface | Controls | Functions | Handling Stelos: Technical Data Stelos: Remote control | Flash triggering Stelos: Power supply | Battery Stelos: Maintenance | Repair | Warranty Stelos: Accessories & Spare Parts Stelos: Error messages
  • Satos
    Satos: Safety Instructions – read before use | Environment Satos: Firmware update Satos Satos: User Interface | Controls | Functions | Handling Satos: Technical Data Satos: Remote control | Flash triggering Satos: Power supply | Battery Satos: Maintenance | Repair | Consumables | Spare parts | Guarantee Satos: Accessories Satos: Charging station for up to 4 slide-in batteries
  • Pulso L
    Pulso L: Safety Instructions – read before use | Environment Pulso L: Firmware update Pulso L: User Interface | Controls | Functions | Handling Pulso L: Technical Data Pulso L: Maintenance | Repair | Consumables | Spare parts | Guarantee Pulso L: Accessories
  • Siros S
    Siros S: Safety Instructions – read before use | Environment Siros S: Firmware update Siros S: User Interface | Controls | Functions | Handling Siros S: Technical Data Siros S: Remote control | Flash triggering Siros S: Power supply Siros S: Maintenance | Repair | Consumables | Spare parts | Guarantee Siros S: Accessories
  • Siros L
    Siros L: Safety Instructions – read before use | Environment Siros L: Firmware update Siros L Siros L: User Interface | Controls | Functions | Handling Siros L: Technical Data Siros L: Remote control | Flash triggering Siros L: Power supply | Battery Siros L: Maintenance | Repair | Consumables | Spare parts | Guarantee Siros L: Accessories
  • Scoro E + S
    Scoro E & S: Safety instructions - read before use | Environment Scoro E & S: User interface | Controls | Functions | Handling Scoro E & S: Technical Data Scoro E & S: Remote control | Flash triggering Scoro E & S: Maintenance | Repair | Consumables | Spare parts | Guarantee
  • Move 1200 L
    Safety Instructions – please read before use | Environment Firmware update Move User Interface | Functions | Handling | Controls Technical Data Remote control | Flash triggering Power supply | Battery Maintenance | Repair | Consumables | Spare parts
  • RFS 2.1
    RFS 2.1: Safety Instructions - read before use RFS 2.1: Scope of Delivery and product overview RFS 2.1: Technical Data RFS 2.1: Operation as transmitter or receiver RFS 2.1: transceiver as transmitter RFS 2.1: Trouble shooting RFS 2.1: Accessories
  • RFS 2.2
    RFS 2.2: Safety Instructions - read before use RFS 2.2: Scope of Delivery and product overview (RFS 2.2) RFS 2.2: transceiver as transmitter RFS 2.2 transceiver as receiver RFS 2.2: Technical Data RFS 2.2: Firmware Update
  • RFS 3
    RFS 3: Safety Instructions – read before use | Environment RFS 3: Scope of delivery and operating elements RFS 3: User Interface | Controls | Functions | Handling RFS 3: Firmware Update RFS 3.0 RFS 3: Compatibility RFS 3: Technical Data RFS 3: Maintenance | Repair | Consumables | Spare parts | Guarantee RFS 3: Trouble shooting
  • Pulso G, Unilite and Picolite
  • LED F160
    LED F160: Safety instructions - read before use | Environment LED F160: Firmware Update LED F160 LED F160: User Interface | Controls | Functions | Handling LED F160: Technical Data LED F160: Maintenance | Repair | Error Messages| Guarantee LED F160: Accessories
  • Scope D50
    Scope D50: Videos
  • Compatibility (Lamp <-> light shaper | Lamp <-> power pack)
  • Locate your distributor or dealer
+ More
  • Stelos 800 L

    • Satos

      • Pulso L

        • Siros S

          • Siros L

            • Scoro E + S

              • Move 1200 L

                • RFS 2.1

                  • RFS 2.2

                    • RFS 3

                      • Pulso G, Unilite and Picolite

                        • LED F160

                          • Scope D50

                            • Compatibility (Lamp <-> light shaper | Lamp <-> power pack)

                              • Locate your distributor or dealer

                                When you switch the power pack on, the main menu screen appears. From there you have access
                                to various functions. The only menu language available is English.
                                1) To enter the main menu, press the "menu / enter" key.
                                2) Use the "q/p" keys to reach the menu item you want.
                                3) Confirm your choice with “menu / enter”.

                                 

                                Display Selection options Description
                                modelling light 10 s
                                30 s
                                60 s
                                cont
                                Time the modelling light is switched on to conserve the battery. 
                                “cont” mode for continuous operation
                                sequence off
                                2 - 50
                                Selection of a certain number of flash releases from 2 - 50. As soon as activated, the info display shows the number in the selected sequence (e.g.: seq15)
                                flash duration opt
                                min
                                Choice of flash duration
                                opt: optimum colour temperature over entire control range.
                                min: fastest possible flash duration for selected energy
                                audio ready signal on
                                off
                                Switches acoustic ready signal on or off
                                studio address 1 - 99 Assignment of studio address from 1 - 99
                                lamp address 1 - 40 Assignment of lamp address from 1 - 40
                                hs on
                                off
                                Switches broncolor “HS” function on or off

                                 

                                 