Information and error messages * - Siros S
Acoustic signals
Beep sound | end of charging or discharging |
Double beep | energy demand above or below energy control setting via RFS 2.1 / 2.2 transmitter |
Message in display
Error 1 (f1) |
No flash after triggering → Is the ignition wire correctly connected? Is the flash tube correctly installed? Otherwise replace flash tube |
Error 2 (f2) |
Afterglow → Switch the unit off and then on again. If this fault occurs repeatedly, the flash tube is defective |
Error 3 (f3) |
Electronics defective → Unit must be sent to service for repair |
Error 4 (f4) |
Overvoltage in flash capacitors → Unit must be sent to service for repair |
Error 5 (f5) |
Thermal alarm, capacitors overheated → A cooling phase of approximately 20 minutes starts. Do not switch the unit off! |
* Error messages are always also indicated by the red cognition light