Acoustic signals & error messages
Acoustic signals
Beep sound | end of charging or discharging |
Double beep | energy demand above or below energy control setting via RFS 2.1 / RFS 2.2 transmitter |
Message in display (*)
Fault 1 (F1) |
No flash on release Is the ignition wire correctly connected? Is the flash tube correctly installed? Otherwise replace flashtube. If this fault still appears, unit must be sent to Service for repair. |
Fault 2 (F2) |
Afterglow Switch the unit off (wait 60 sec.) and then switch it on again. If this fault occurs repeatedly, the flash tube is defective. Please replace it with a new flash tube. If this fault still appears, unit must be sent to Service for repair. |
Fault 3 (F3) |
No charging Unit must be sent to Service for repair. |
Fault 4 (F4) |
Overcharging Unit must be sent to Service for repair. |
th |
Thermal alarm, capacitors overheated A cooling phase of approximately 20 minutes starts. Do not switch off the unit! |
* Error messages are always also indicated by the red cognition light.