Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Contact Us
English (US)
US English (US)
FR French
DE German
  • Home
  • Siros L
  • User Interface | Functions | Handling | Controls

Special functions - Move 1200 L

Written by Myrtha Chollet

Updated at February 23rd, 2023

Contact Us

If you still have questions or prefer to get help directly from an agent, please submit a request.
We’ll get back to you as soon as possible.

Please fill out the contact form below and we will reply as soon as possible.

  • Satos
    Safety Instructions – read before use | Environment Firmware update Satos User Interface | Controls | Functions | Handling Technical Data Remote control | Flash triggering Power supply | Battery Maintenance | Repair | Consumables | Spare parts | Guarantee Accessories Charging station for up to 4 slide-in batteries
  • Pulso L
    Safety Instructions – read before use | Environment Firmware update Pulso L User Interface | Controls | Functions | Handling Technical Data Maintenance | Repair | Consumables | Spare parts | Guarantee Accessories
  • Siros S
    Safety Instructions – read before use | Environment Firmware update Siros S User Interface | Controls | Functions | Handling Technical Data Remote control | Flash triggering Power supply Maintenance | Repair | Consumables | Spare parts | Guarantee Accessories
  • Siros L
    Safety Instructions – read before use | Environment Firmware update Siros L User Interface | Controls | Functions | Handling Technical Data Remote control | Flash triggering Power supply | Battery Maintenance | Repair | Consumables | Spare parts | Guarantee Accessories
  • Scoro E + S
    Safety instructions - read before use | Environment User interface | Controls | Functions | Handling Technical Data Remote control | Flash triggering Maintenance | Repair | Consumables | Spare parts | Guarantee
  • Move 1200 L
    Safety Instructions – please read before use | Environment Firmware update Move User Interface | Functions | Handling | Controls Technical Data Remote control | Flash triggering Power supply | Battery Maintenance | Repair | Consumables | Spare parts
  • RFS 2.1
    Safety Instructions - read before use Scope of Delivery and product overview Technical Data Operation as transmitter or receiver RFS 2.1 transceiver as transmitter Trouble shooting Accessories
  • RFS 2.2
    Safety Instructions - read before use Scope of Delivery and product overview RFS 2.2 transceiver as transmitter RFS 2.2 transceiver as receiver Technical Data Firmware Update RFS 2.2
  • RFS 3
    Safety Instructions – read before use | Environment Scope of delivery and operating elements User Interface | Controls | Functions | Handling Firmware Update RFS 3.0 Compatibility Technical Data Maintenance | Repair | Consumables | Spare parts | Guarantee Trouble shooting
  • Pulso G, Unilite and Picolite
  • LED F160
    Safety instructions - read before use | Environment Firmware Update LED F160 User Interface | Controls | Functions | Handling Technical Data Maintenance | Repair | Error Messages| Guarantee Accessories
  • Scope D50
    Videos
  • Compatibility (Lamp <-> light shaper | Lamp <-> power pack)
  • Locate your distributor or dealer
+ More
  • Satos

    • Pulso L

      • Siros S

        • Siros L

          • Scoro E + S

            • Move 1200 L

              • RFS 2.1

                • RFS 2.2

                  • RFS 3

                    • Pulso G, Unilite and Picolite

                      • LED F160

                        • Scope D50

                          • Compatibility (Lamp <-> light shaper | Lamp <-> power pack)

                            • Locate your distributor or dealer

                              1. Reset (works settings)
                                Press the "test" key for 4 s. This resets all functions to the works settings. Resetting is
                                acknowledged with a double beep.
                                 
                              2. Submenu
                                To enter the submenu for the power pack, hold the "menu / enter" key pressed for 4 s.
                                 
                              Display Options Description
                              daily counter   Number of flashes since the last reset
                              (reset with the "menu / enter" key)
                              flash counter   Number of flashes since the power pack
                              was shipped
                              energy unit J
                              Ws
                              Choice of unit for energy on the info display
                              serial number   Displays the serial number. Only for Service
                              country   Displays the country code. Only for Service
                              Power timeout 16 - 120 min Automatically switches the power pack
                              off after so many minutes without use
                              prog.version   Displays the program version. Only for Service

                              Was this article helpful?

                              Yes
                              No
                              Give feedback about this article

                              Related Articles

                              • Info display - Move 1200 L
                              • Overview of main menu functions - Move 1200 L
                              • Controlling flash times - Move 1200 L
                              • Menu navigation - Move 1200 L

                              Copyright 2025 – broncolor.

                              Knowledge Base Software powered by Helpjuice

                              Expand