Information and fault signals - Move 1200 L
Message in display | Description |
Thermo 1 | Charging circuit overheated (cooling phase = 15 min) |
Thermo 2 | Capacitors overheated (cooling phase = 60 min) |
Thermo 3 | Resistors overheated (cooling phase = 3 min) |
Thermo 4 | Battery overheated (cooling phase = 15 min) |
Thermo 5 | Battery overheated (cooling phase = 20 min) |
Accu low 20 % | Appears on reaching 20 % energy remaining in battery |
Charge defect | Unit must be sent to Service for repair |
Overvoltage | Unit must be sent to Service for repair |
Defect lamp 1 / lamp 2 | Lamp 1 or lamp 2 is defective or not correctly connected |
Use broncolor tubes | Please use only original broncolor flash tubes |
Acoustic fault indicator
If the flash fails to fire, a warning signal sounds for ca. 0.5 s and the display for the appropriate lamp blinks.
Acoustic signals
Beep sound:
End of charging or discharging
Double beep:
Energy demand above or below energy control setting via RFS 2 transmitter
"test" key held pressed for 4 s (reset to works settings)